Description of the Moduflow self-priming liquid ring pumps
A range of medium pressure low volume liquid ring pumps made from die-pressed stainless steel aisi 304 or aisi 316 with capacities up to 13.8m3 per hour and heads up to 60m sold either as wet end alone; pump and motor; or pump and motor with trolley mount.
The Moduflow pumps feature :
*Manufacture to ISO 90002 norms
*Entirely die-pressed from heavy duty 4mm thick sheet metal aisi 304 or aisi 316
*High resistance to corrosion
*Smooth internal surfaces
*Impellers from stainless steel aisi 316
*Light weight and limited dimensions
*Monoblock coupling
*Reduced maintenance
*Motors enclosed externally ventilated with IP55 protection suitable for continuous duty.
*ADPE (explosion proof) motors available.
*Mechanical rotative type seals with buna (NBR), viton(R), or teflon(R) rings
*Temperature up to 100 degrees centigrade
*Maximum system pressure 7 bar.
*Built in filter
*Built in by-pass enabling variation of capacity and pressure.
Applications
Moduflow pumps are for use with clean liquids including acids and solvents compatible with the type of stainless steel and seal used, in industrial systems wherever liquids tend to get dirty, abrasive, slightly aggressive, and in particular in industries such by way of example as the textiles, dyeing, washing, printing, galvanics industries and with inflammable liquids subject to the use of ADPE explosion proof motors.
Because of the built-in variable pressure and capacity features offered by the by-pass, Moduflow pumps are particularly suited for use with wine presses and filters in general. They can be used for alimentary liquids where strictly sanitary hygienic pumps are not required. (For hygienic pumps please refer to information on: Milky Whey sanitary centrifugal pumps, Milky Whey RVflexible vane pumps, and Milky Whey LR liquid ring sanitary pumps.
Other areas for application include the light pharmaceuticals, depuration, and petrochemicals industries.
Do NOT use Moduflow pumps for:
Liquids which are incompatible with the materials used, amongst which in particular and BY WAY OF EXAMPLE, chloric acid, hydrochloric acid in any concentration, silver chloride, hydrofluoric acid, muriatic acid, sulphuric acid, hydrobromic acid, molten antimony and aluminium, ammonia, sulphur chloride.
Use and operation of the by-pass or pressure controller.
For references to parts numbers please refer to the DRAWING ot the Moduflow pumps.
The by-pass mechanism built into the pump allows the maximum pressure of the pump to be varied, and therefore capacity at the various heads to be reduced or increased. A valve (08) activated by a spring (07) the force of which is controlled by turning the knob (04) and the piston (05) closes a passage which communicates with the compression chamber. So long as there is no pressure, as for instance during liquid transfer, the by-pass cannot work. In the presence of a pressure in the pipes caused for instance by a tap or a filter, or head, the pressure inside the pump will tend to open the by-pass control, allowing recirculation of part of the liquid into the suction chamber of the pump. At that point it is possible to regulate both capacity and pressure. During liquid transfer the device is particularly useful as when it is adjusted to its minimum, the pump outlet can be closed without stopping the pump. Numerous recipients can thus be filled by simply turning a tap or ball valve on or off.
SPECIFICATIONS
Capacity
All readings are with water at 15 degrees centigrade, specific weight 1000 F/m3 and atmospheric pressure equal to 750mm Hg and are accurate to +/- 5%
Moduflow pumps with 4 pole 1400 rpm motors
Moduflow 110 0.3HP (1 PHASE) 0.5HP (3 PHASE) 1400 RPM INLET AND OUTLET 1" MALE GAS THREADED SINGLE OR THREE PHASE
Head in meters | 3 | 6 | 9 | 12 | 00 |
Liters/minute | 035 | 020 | 012 | 007 | 000 |
Moduflow 130 0.75HP 1400 RPM INLET/OUTLET 1 1/4" MALE GAS THREAD SINGLE PHASE
Head in meters | 2 | 5 | 10 | 15 | 19 |
|
Liters/minute | 075 | 065 | 050 | 040 | 013 |
Moduflow 150 2.5HP 1400 RPM INLET/OUTLET 1 1/2" MALE GAS THREAD THREE PHASE ONLY
Head in meters | 5 | 10 | 15 | 20 | 22 | 00 |
Liters/minute | 120 | 105 | 075 | 025 | 010 | 000 |
Moduflow pumps with 2 pole 2800 rpm motors
Moduflow 110 0.5HP 2800 RPM INLET AND OUTLET 1" gas male thread SINGLE PHASE
Head in meters | 2 | 5 | 10 | 15 | 18 | 20 |
Liters/minute | 070 | 065 | 050 | 045 | 035 | 030 |
Moduflow 110 0.75HP 2800 RPM INLET AND OUTLET 1" gas male thread THREE PHASE
Head in meters | 2 | 5 | 10 | 15 | 20 | 25 | 30 |
Liters/minute | 075 | 070 | 050 | 045 | 040 | 025 | 015 |
Moduflow 130 1.5HP single phase and 2HP three phase INLET/OUTLET 1 1/4" gas male thread
Head in meters | 5 | 10 | 15 | 20 | 25 | 30 | 35 |
Liters/minute | 115 | 100 | 095 | 080 | 075 | 065 | 050 |
Moduflow 130 2.5HP INLET/OUTLET 1 1/4" gas male thread THREE PHASE
Head in meters | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 |
Liters/minute | 120 | 110 | 100 | 090 | 080 | 070 | 055 | 50 | 35 |
Moduflow 150 4.5HP 2800 RPM INLET/OUTLET 1 1/2" male gas thread THREE PHASE
Head in meters | 5 | 10 | 15 | 20 | 25 | 30 | 35 |
Liters/minute | 230 | 220 | 200 | 190 | 170 | 155 | 140 |
Moduflow 150 6HP 2800 RPM INLET/OUTLET 1 1/2" male gas thread THREE PHASE
Head in meters | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 |
Liters/minute | 230 | 220 | 200 | 190 | 170 | 155 | 140 | 130 | 120 | 095 | 045 | 030 |
Motor specifications
Motors are NOT standard because of the special flange required to make the close coupling with the pump.
They are enclosed externally ventilated type with protection IP55 for continuous duty.
Explosion-proof three phase motors are available for all pump sizes. Special voltages and/or tropicalisation of motors are available on request, subject to the payment of an extra price.
Acoustic pressure (noise) in decibels
Moduflow 110
The noise level at open outlet is less than 70 dBA
Moduflow 130
The noise level at open outlet is 74.3 dBA
The noise level at head 10m is 70.5 dBA
Moduflow 150
The noise level at head 15m is 78.9 dBA
The noise level at 35m head is 79.5 dBA
The noise level at maximum head is 74.5 dBA
Seals
OPERATING LIMITS
Pressure : 6 bar
Fluid speed: 12 meters/second
Temperature : -30 degrees C to 90 degrees C
SEAL PARTS AND MATERIALS
Part 01 | Rotating part-seal support | steel |
Part 02 | Rotating part-spring | steel |
Part 03 | Rotating part-stop ring | steel |
Part 04 | Rotating part-seal | with buna or viton(R) or teflon(R) rings
|
Part 05 | Rotating part-external casing | steel |
Part 06 | Rotating part-contact ring | graphite
|
Part 07 | Fixed part-counterface | ceramic |
Part 08 | Fixed part-seal | with buna, viton(R) or teflon(R) rings |
SEAL DIMENSIONS
Codes
d1 | Shaft diameter |
d3 | External diameter of seal |
i3 | Height of rotating part of seal |
d4 | Seal chamber diameter |
d7 | Diameter of fixed part of seal |
i4 | Height of fixed part of seal |
d6 | Diameter of shaft passage |
i1 | Total height of seal |
Model | d1 | d3 | i3 | d4 | d7 | i4 | d6 | i1 |
Moduflow 110 with buna/viton(R) rings | 18 | 40 | 14 | 38 | 40 | 10 | 21 | 23 |
Moduflow 110 with teflon(R) rings | 20 | 42 | 28 | 42 | 21 | 09 | 21 | 37 |
Moduflow 130 with buna/viton(R) rings | 25 | 48 | 14 | 45 | 48 | 10 | 27 | 35 |
Moduflow 130 with teflon(R) rings | 25 | 50 | 28 | 38 | 50 | 09 | 27 | 40 |
Moduflow 150 with buna/viton(R) rings | 25 | 48 | 14 | 45 | 48 | 10 | 27 | 35 |
Moduflow 150 with teflon(R) | 25 | 50 | 28 | 38 | 50 | 09 | 27 | 40 |
(Viton(R) and Teflon(R) are registered trademarks of DuPont Dow Elastomers).
FOR MORE INFORMATION ON THE MODUFLOW PUMPS PLEASE GO TO
PRICES AND SALES CONDITIONS
RETURN TO:
If you cannot find the information you require on these pages, please contact Terry Manning
by e-mail on : pumps@flowman.nl or
telephone or fax him at 0031-227-604128.
E-mail Terry Manning